Switched POPS Cost Sensitive
- Home
- Switched POPS Cost Sensitive
The Server Technology® PRO2 Switched POPS PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® and POPS® technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input and at each output. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Switched POPS “Master” PDU can be connected to as many as three (with optional module) PRO2 Switched POPS “Link” PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.
PRO2 Switched POPS STV-6541 3.3kW - 7.3kW (18) C13 and (6) C19 outlets
Key Features
Family Specifications
Branch Monitoring: | Current (A) | Power Pivot Input: | No |
Branch Overcurrent Protection: | 5 kAIC | Product Height (inch): | 64.0 |
Branch Overcurrent Protection Type: | Circuit Breaker: 2-pole | Product Height (mm): | 1626 |
Dual Input: | No | Product Max Depth (inch): | 3.5 |
High Retention Outlets: | Yes | Product Max Depth (mm): | 89 |
Input Current Display: | Auto-Orient | Product Nominal Depth (inch): | 3.5 |
Input Monitoring: | PIPS | Product Nominal Depth (mm): | 89 |
Locking Outlets: | Yes | Product Width (inch): | 1.75 |
Max Operating Temperature: | 60 °C | Product Width (mm): | 45 |
Fast Movers: | No | ||
Mounting: | 0U Vertical | ||
Outlet Monitoring: | POPS | ||
PDU Platform: | PRO2 |
Product Specifications
STV-6541K (Switched POPS)
Input Power Capacity (kW): | 7.3 |
Input Plug Type: | IEC 230V/32A 2P+PE 6Hr |
Input Current (A): | 32 |
Input Current Rated (A): | 32 |
Input Nominal Voltage (V): | 230 |
Input Phase: | 1-Phase (L-N) |
Input Cord Location: | Bottom/Front |
Outlet Form Factor: | Conventional |
Total Outlets: | 24 |
IEC C13 Count: | 18 |
IEC C19 Count: | 6 |
Drawings
Design Diagram – DD 412-1219-10
Documents
Firmware
Manual
Application Notes
Technical Notes
- TN - About "Bluetooth Ready" (303-9999-40)
- TN - CDU Firmware Upgrade Instructions (303-9999-35)
- TN - Introducing PRO1 (303-9999-41)
- TN - Monitoring Solution Featuring Bluetooth® and ST Eye Mobile App (for Google Android) (303-9999-26)
- TN - Monitoring Solution Featuring Bluetooth® and ST Eye Mobile App for PRO2 (for Apple iOS) (303-9999-33)
- TN - Monitoring Solution Featuring Bluetooth® and ST Eye Mobile App for PRO2 (for Google Android) (303-9999-32)
- TN - PDU Security (303-9999-12)
- TN - Using LDAP with Sentry Firmware and Sentry Power Manager (SPM) (303-9999-30)
- TN - Using StartUp Stick for CDU Mass Configuration (303-9999-34)
- TN - Zero Touch Provisioning (303-9999-44)
White Papers
- WP - Advances in Power and Environmental Monitoring for Increasing Efficiency in the Data Center
- WP - Bottom-Up Data Center Power Management
- WP - Managing variable data center rack densities
- WP - Mission Critical - Rack Power Distribution
- WP - Power Distribution as a System within the High-Density Data Center
- WP - The Practical Science of Data Center Capacity Planning