Switched Cost Sensitive
- Home
- Switched Cost Sensitive
The Server Technology® Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® technology provides accurate measurement of current (billing-grade), voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The Switched “Master” PDU can be connected to a Switched “Link” PDU to extend the network access to the redundant or secondary power feed.
Switched STV-4102 3.3kW - 7.3kW (24) C13 outlets
Key Features
Family Specifications
Branch Monitoring: | Sense | Power Pivot Input: | Yes |
Branch Overcurrent Protection: | 5 kAIC | Product Height (inch): | 69.0 |
Branch Overcurrent Protection Type: | Circuit Breaker: 2-pole | Product Height (mm): | 1753 |
Dual Input: | No | Product Max Depth (inch): | 2.25 |
High Retention Outlets: | Yes | Product Max Depth (mm): | 58 |
Input Current Display: | Auto-Orient | Product Nominal Depth (inch): | 2.25 |
Input Monitoring: | PIPS | Product Nominal Depth (mm): | 58 |
Locking Outlets: | Yes | Product Width (inch): | 1.75 |
Max Operating Temperature: | 60 °C | Product Width (mm): | 45 |
Fast Movers: | Yes | ||
Mounting: | 0U Vertical | ||
Outlet Monitoring: | None | ||
PDU Platform: | CDU1 |
Product Specifications
STV-4102K (SWITCHED)
Input Power Capacity (kW): | 7.3 |
Input Plug Type: | IEC 230V/32A 2P+PE 6Hr |
Input Current (A): | 32 |
Input Current Rated (A): | 32 |
Input Nominal Voltage (V): | 230 |
Input Phase: | 1-Phase (L-N) |
Input Cord Location: | Bottom/Pivot |
Outlet Form Factor: | Conventional |
Total Outlets: | 24 |
IEC C13 Count: | 24 |
Utility Outlet: | 0 |
STV-4102J (SWITCHED)
Input Power Capacity (kW): | 3.6 |
Input Plug Type: | IEC 230V/16A 2P+PE 6Hr |
Input Current (A): | 16 |
Input Current Rated (A): | 16 |
Input Nominal Voltage (V): | 230 |
Input Phase: | 1-Phase (L-N) |
Input Cord Location: | Bottom/Pivot |
Outlet Form Factor: | Conventional |
Total Outlets: | 24 |
IEC C13 Count: | 24 |
Utility Outlet: | 0 |
STV-4102M (SWITCHED)
Input Power Capacity (kW): | 7.3 |
Input Plug Type: | 230V Clipsal 56P332 |
Input Current (A): | 32 |
Input Current Rated (A): | 32 |
Input Nominal Voltage (V): | 230 |
Input Phase: | 1-Phase (L-N) |
Input Cord Location: | Bottom/Pivot |
Outlet Form Factor: | Conventional |
Total Outlets: | 24 |
IEC C13 Count: | 24 |
Utility Outlet: | 0 |
Drawings
Design Diagram – DD 412-0771-2
Wiring Diagram – WD 495-0958-2
Documents
Firmware
Manual
Application Notes
Technical Notes
- TN - About "Bluetooth Ready" (303-9999-40)
- TN - CDU Firmware Upgrade Instructions (303-9999-35)
- TN - CDU Security (303-9999-12)
- TN - Introducing PRO1 (303-9999-41)
- TN - Monitoring Solution Featuring Bluetooth® and ST Eye Mobile App (for Google Android) (303-9999-26)
- TN - Monitoring Solution Featuring Bluetooth® and ST Eye Mobile App for PRO2 (for Apple iOS) (303-9999-33)
- TN - Monitoring Solution Featuring Bluetooth® and ST Eye Mobile App for PRO2 (for Google Android) (303-9999-32)
- TN - Using LDAP with Sentry Firmware and Sentry Power Manager (SPM) (303-9999-30)
- TN - Using StartUp Stick for CDU Mass Configuration (303-9999-34)
White Papers
- WP - Advances in Power and Environmental Monitoring for Increasing Efficiency in the Data Center
- WP - Bottom-Up Data Center Power Management
- WP - Managing variable data center rack densities
- WP - Mission Critical - Rack Power Distribution
- WP - Power Distribution as a System within the High-Density Data Center
- WP - The Practical Science of Data Center Capacity Planning