Smart POPS Feature Rich
- Home
- Smart POPS Feature Rich
POPS® Smart & Switched PDU Adds Per Outlet Power Sensing (POPS) to Smart or Switched PDUs to provide power monitoring per an individual outlet/device. Power information per individual outlet /device includes current, voltage, power (kW), apparent power, crest factor, and power factor. Using our grouping technology, power information is available per device, groups of devices (application), individual PDU or cabinet.
PRO2™ HDOT® 11.0kW - 22.0kW (36-42) outlets
Key Features
Family Specifications
Branch Monitoring: | Current (A) | Power Pivot Input: | No |
Branch Overcurrent Protection: | 10 kAIC | Product Height (inch): | 70 |
Branch Overcurrent Protection Type: | Circuit Breaker: 1-pole | Product Height (mm): | 1778 |
Dual Input: | No | Product Max Depth (inch): | 3 |
High Retention Outlets: | Yes | Product Max Depth (mm): | 77 |
Input Current Display: | Auto-Orient | Product Nominal Depth (inch): | 2.5 |
Input Monitoring: | PIPS | Product Nominal Depth (mm): | 64 |
Locking Outlets: | Yes | Product Width (inch): | 2.2 |
Max Operating Temperature: | 60 °C | Product Width (mm): | 56 |
Fast Movers: | No | ||
Mounting: | 0U Vertical | ||
Outlet Monitoring: | Determined By Outlet Module | ||
PDU Platform: | Pro2 |
Product Specifications
C2SG36CE-4PAF2M00 (SMART POPS)
Input Power Capacity (kW): | 22 |
Input Plug Type: | 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr |
Input Current (A): | 32 |
Input Current Rated (A): | 32 |
Input Nominal Voltage (V): | 400 |
Input Phase: | 3-Phase Wye (L-N) |
Input Cord Location: | Bottom/End |
Alternating Phase Outlets: | Yes |
Outlet Form Factor: | HDOT |
Total Outlets: | 36 |
IEC C13 Count: | 36 |
C2S36CE-4PAF2M66 (SMART)
Input Power Capacity (kW): | 22 |
Input Plug Type: | 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr |
Input Current (A): | 32 |
Input Current Rated (A): | 32 |
Input Nominal Voltage (V): | 400 |
Input Phase: | 3-Phase Wye (L-N) |
Input Cord Location: | Bottom/End |
Alternating Phase Outlets: | Yes |
Outlet Form Factor: | HDOT |
Total Outlets: | 36 |
IEC C13 Count: | 24 |
IEC C19 Count: | 12 |
Drawings
Documents
Firmware
Manual
Application Notes
- AN PRO2-001: How do I maximize uptime using power data from the equipment cabinet?
- AN PRO2-002: How do I use a cabinet PDU to help manage equipment deployment?
- AN SPM-001: How do I leverage cabinet PDU information to help plan for growth?
- AN HDOT Smart PDU’s Power Cisco’s Unified Computing System
- AN HDOT-001: How do I maximize the number of devices in my small 24"x 42U cabinets?
- AN HDOT-004: How do I provide 10kW in a rack with only single-phase power available?
- AN PRO2-003: How do I get performance metrics from non-intelligent power supplies?
- AN SPM-001: How do I leverage cabinet PDU information to help plan for growth?
Technical Notes
- TN - About "Bluetooth Ready" (303-9999-40)
- TN - CDU Firmware Upgrade Instructions (303-9999-35)
- TN - CDU Security (303-9999-12)
- TN - Introducing PRO1 (303-9999-41)
- TN - Monitoring Solution Featuring Bluetooth® and ST Eye Mobile App (for Google Android) (303-9999-26)
- TN - Monitoring Solution Featuring Bluetooth® and ST Eye Mobile App for PRO2 (for Apple iOS) (303-9999-33)
- TN - Monitoring Solution Featuring Bluetooth® and ST Eye Mobile App for PRO2 (for Google Android) (303-9999-32)
- TN - Using LDAP with Sentry Firmware and Sentry Power Manager (SPM) (303-9999-30)
- TN - Using StartUp Stick for CDU Mass Configuration (303-9999-34)
- TN - About "Bluetooth Ready" (303-9999-40)
- TN - CDU Firmware Upgrade Instructions (303-9999-35)
- TN - CDU Security (303-9999-12)
- TN - Introducing PRO1 (303-9999-41)
- TN - Monitoring Solution Featuring Bluetooth® and ST Eye Mobile App (for Google Android) (303-9999-26)
- TN - Monitoring Solution Featuring Bluetooth® and ST Eye Mobile App for PRO2 (for Apple iOS) (303-9999-33)
- TN - Monitoring Solution Featuring Bluetooth® and ST Eye Mobile App for PRO2 (for Google Android) (303-9999-32)
- TN - Using LDAP with Sentry Firmware and Sentry Power Manager (SPM) (303-9999-30)
- TN - Using StartUp Stick for CDU Mass Configuration (303-9999-34)
White Papers
- WP - Advances in Power and Environmental Monitoring for Increasing Efficiency in the Data Center
- WP - Bottom-Up Data Center Power Management
- WP - Managing variable data center rack densities
- WP - Mission Critical - Rack Power Distribution
- WP - Power Distribution as a System within the High-Density Data Center
- WP - The Practical Science of Data Center Capacity Planning
- WP - Advances in Power and Environmental Monitoring for Increasing Efficiency in the Data Center
- WP - Bottom-Up Data Center Power Management
- WP - Managing variable data center rack densities
- WP - Mission Critical - Rack Power Distribution
- WP - Power Distribution as a System within the High-Density Data Center
- WP - The Practical Science of Data Center Capacity Planning