The Server Technology® PRO2 Smart/Switched POPS PDU provides control of outlet power(Switched only) and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® and POPS® technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input and at each output (POPS only). These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Smart/Switched POPS “Master" PDU can be connected to as many as three (with optional module) PRO2 Smart/Switched POPS “Link" PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.
PRO2™ HDOT® 11.0kW - 22.0kW (36-42) outlets |
Family Specifications |
Product Specifications |
C2WG36CE-4PAF2M66 (SWITCHED POPS) DOWNLOAD DATASHEET |
C2WG36CE-4PAF2M00 (SWITCHED POPS) DOWNLOAD DATASHEET |
Drawings |
Design Diagram - DD 412-0983-42H
Wiring Diagram - WD 495-0983-42H
Visio Drawing - Pro2 HDOT.vss
Documents |
Firmware
Manual
UG - C2S Series Smart PRO2 – User Guide (Firmware Version 8.0)
UG - C2W Series Switched PRO2 – User Guide (Firmware Version 8.0)
Application Notes
AN PRO2-001: How do I maximize uptime using power data from the equipment cabinet?
AN PRO2-002: How do I use a cabinet PDU to help manage equipment deployment?
AN SPM-001: How do I leverage cabinet PDU information to help plan for growth?
AN HDOT Smart PDU’s Power Cisco’s Unified Computing System
AN HDOT-001: How do I maximize the number of devices in my small 24"x 42U cabinets?
AN HDOT-004: How do I provide 10kW in a rack with only single-phase power available?
AN PRO2-003: How do I get performance metrics from non-intelligent power supplies?
AN SPM-001: How do I leverage cabinet PDU information to help plan for growth?
Technical Notes
TN - About "Bluetooth Ready" (303-9999-40)
TN - CDU Firmware Upgrade Instructions (303-9999-35)
TN - CDU Security (303-9999-12)
TN - Introducing PRO1 (303-9999-41)
TN - Using LDAP with Sentry Firmware and Sentry Power Manager (SPM) (303-9999-30)
TN - Using StartUp Stick for CDU Mass Configuration (303-9999-34)
White Papers
WP - Advances in Power and Environmental Monitoring for Increasing Efficiency in the Data Center
WP - Bottom-Up Data Center Power Management
WP - Managing variable data center rack densities
WP - Mission Critical - Rack Power Distribution
WP - Power Distribution as a System within the High-Density Data Center
WP - The Practical Science of Data Center Capacity Planning
WP - Advances in Power and Environmental Monitoring for Increasing Efficiency in the Data Center
WP - Bottom-Up Data Center Power Management
WP - Managing variable data center rack densities
WP - Mission Critical - Rack Power Distribution
WP - Power Distribution as a System within the High-Density Data Center
WP - The Practical Science of Data Center Capacity Planning
Compliance
Warranty