Aline Technology

Switched Cost Sensitive

The Server Technology® Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® technology provides accurate measurement of current (billing-grade), voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The Switched “Master” PDU can be connected to a Switched “Link” PDU to extend the network access to the redundant or secondary power feed.

switched cost sensitive

 

Switched STV-4102 3.3kW - 7.3kW (24) C13 outlets

 

Key Features

Switched cost sensitive key feature

 

Family Specifications

Branch Monitoring:  Sense  Power Pivot Input:  Yes 
Branch Overcurrent Protection:  5 kAIC  Product Height (inch):  69.0 
Branch Overcurrent Protection Type:  Circuit Breaker: 2-pole  Product Height (mm):  1753 
Dual Input:  No  Product Max Depth (inch):  2.25 
High Retention Outlets:  Yes  Product Max Depth (mm):  58 
Input Current Display:  Auto-Orient  Product Nominal Depth (inch):  2.25 
Input Monitoring:  PIPS  Product Nominal Depth (mm):  58 
Locking Outlets:  Yes  Product Width (inch):  1.75 
Max Operating Temperature:  60 °C  Product Width (mm):  45 
Fast Movers:  Yes     
Mounting:  0U Vertical     
Outlet Monitoring:  None     
PDU Platform:   CDU1     

 

Product Specifications

STV-4102K (SWITCHED) DOWNLOAD DATASHEET

Input Power Capacity (kW): 7.3
Input Plug Type: IEC 230V/32A 2P+PE 6Hr
Input Current (A):  32 
Input Current Rated (A):  32 
Input Nominal Voltage (V):  230
Input Phase:  1-Phase (L-N) 
Input Cord Location:  Bottom/Pivot 
Outlet Form Factor:  Conventional 
Total Outlets:  24 
IEC C13 Count:  24 
Utility Outlet: 

 

STV-4102J (SWITCHED) DOWNLOAD DATASHEET

Input Power Capacity (kW):  3.6 
Input Plug Type:  IEC 230V/16A 2P+PE 6Hr 
Input Current (A):  16 
Input Current Rated (A):  16 
Input Nominal Voltage (V):  230 
Input Phase:  1-Phase (L-N) 
Input Cord Location:  Bottom/Pivot 
Outlet Form Factor:  Conventional 
Total Outlets:  24 
IEC C13 Count:  24 
Utility Outlet: 

 

STV-4102M (SWITCHED) DOWNLOAD DATASHEET

Input Power Capacity (kW):  7.3 
Input Plug Type:  230V Clipsal 56P332 
Input Current (A):  32 
Input Current Rated (A):  32 
Input Nominal Voltage (V):  230 
Input Phase:  1-Phase (L-N) 
Input Cord Location:  Bottom/Pivot 
Outlet Form Factor:  Conventional 
Total Outlets:  24 
IEC C13 Count:  24 
Utility Outlet: 

 

Drawings

Design Diagram -  DD 412-0771-2

Wiring Diagram -  WD 495-0958-2

 

Documents

Firmware

Download Center 

 

Manual

UG - CW Series Switched Cabinet Power Distribution Unit - Installation & Operations (Firmware Version 7.0)

UG - CW Series Switched Cabinet Power Distribution Unit - Smart Load-Shedding Installation & Operations

 

Application Notes

AN PRO2-001: How do I maximize uptime using power data from the equipment cabinet?

AN PRO2-002: How do I use a cabinet PDU to help manage equipment deployment?

AN SPM-001: How do I leverage cabinet PDU information to help plan for growth?

 

Technical Notes   

TN - About "Bluetooth Ready" (303-9999-40)

TN - CDU Firmware Upgrade Instructions (303-9999-35)

TN - CDU Security (303-9999-12)

TN - Introducing PRO1 (303-9999-41)

TN - Monitoring Solution Featuring Bluetooth® and ST Eye Mobile App (for Google Android) (303-9999-26)

TN - Monitoring Solution Featuring Bluetooth® and ST Eye Mobile App for PRO2 (for Apple iOS) (303-9999-33)

TN - Monitoring Solution Featuring Bluetooth® and ST Eye Mobile App for PRO2 (for Google Android) (303-9999-32)

TN - Using LDAP with Sentry Firmware and Sentry Power Manager (SPM) (303-9999-30)

TN - Using StartUp Stick for CDU Mass Configuration (303-9999-34)

 

White Papers 

WP - Advances in Power and Environmental Monitoring for Increasing Efficiency in the Data Center

WP - Bottom-Up Data Center Power Management

WP - Managing variable data center rack densities

WP - Mission Critical - Rack Power Distribution

WP - Power Distribution as a System within the High-Density Data Center

WP - The Practical Science of Data Center Capacity Planning

 

Compliance 

Export Compliance

 

Warranty

Warranty Policy

 

 

 