Aline Technology

Switched -48VDC (2) 600A inputs (16) 125A outputs

The Sentry 48DCWB-16-2X600-E0 Intelligent PDU and Remote Power Manager minimizes the impact of locked-up routers, servers and other network devices on business-critical networks. CLECs, ILECs, ISPs and enterprises use the Sentry 48DCWB-16-2X600-E0 to manage equipment in remote sites, co-location facilities and network operation centers. Sentry 48DCWB-16-2X600-E0 eliminates the need to dispatch a field service technician for manual intervention when devices lock-up. Using a Sentry 48DCWB-16-2X600-E0, the network operations center can quickly restart locked-up remote network servers to ensure that the network is fully operational around the clock.

 

Key Features

Switched 48VDC 2 100A inputs 8 20A outputs key f1

Switched 48VDC 2 100A inputs 8 20A outputs key f2

Switched 48VDC 2 100A inputs 8 20A outputs key f3

 

Family Specifications

Branch Monitoring: None Power Pivot Input:  No 
Branch Overcurrent Protection:  100 kA  Product Height (inch):  7.0 
Branch Overcurrent Protection Type:  Circuit Breaker/Fuses  Product Height (mm):  178 
Dual Input:  Yes  Product Max Depth (inch):  32.0 
High Retention Outlets:  No  Product Max Depth (mm):  813 
Input Current Display:  None  Product Nominal Depth (inch):  32.0 
Input Monitoring:  None  Product Nominal Depth (mm):  813 
Locking Outlets:  No  Product Width (inch):  17.0 
Max Operating Temperature:  40 °C  Product Width (mm):  432 
Fast Movers:  No     
Mounting:  4U Horizontal     
Outlet Monitoring:  Current (A)     
PDU Platform:  CDU1     

 

Product Specifications

48DCWB-16-2X600-E0 (-48 VDC)  DOWNLOAD DATASHEET

Input Power Capacity (kW):  57.6 
Input Plug Type:  Other 
Input Current (A):  1200 
Input Current Rated (A):  1200 
Input Nominal Voltage (V):  -48 
Input Phase:  DC 
Input Cord Location:   
Outlet Form Factor:   
Total Outlets:  16 
Other Outlets:  16 

 

Drawings

Design Drawings - DD 412-48125-4

 

Documents

Firmware

Download Center

 

Manual

UG - (-48 VDC) 300A and 600A Remote Power Manager - Installation and Operations Manual (v7.0)

UG - (-48 VDC) 75A and 100A Remote Power Manager - Installation & Operations manual (v7.0)

 

Application Notes 

AN 48VDC-001: How can I monitor and manage DC power for a rack with two Juniper MX960’s? 

 

Technical Notes  

TN - Sentry -48VDC Fuses and Circuit Breakers 

TN - Using LDAP with Sentry Firmware and Sentry Power Manager (SPM) (303-9999-30)

 

Compliance

Export Compliance

 

Warranty

Warranty Policy 

 

 

 

Talk to Us Today!

Contact us by phone + 64 9 579 4799 or e-mail us sales@aline.co.nz for any inquiries about power distribution unit.